Resolved Issue

Ticket Number: 58622

Sales Consolidated report vs Venezuela

09/05/2006 9:52:42 AM

Dev - BO

Issue Reported in Version:

2005 SP2 HF3

Found By:

AS POS

Issue:

The sales consolidated report is no longer showing the correct value.
This report was working properly in 2005 SP1 and it is no longer working in SP2.

 

Resolution

Resolution Version:

2005 SP4 (7.4) RC4

Resolution Notes:

To force the Sales Consolidated report to print with proper decimal values in Venezuela, add the following configuration key and value in the [Miscellaneous] section of the Bo.ini file under the C:\Posera\MaitreD\Data directory:

ForceToUseTwoDecimals=True

Note: When modifying the Bo.ini, first stop the Server through Server Control, then exit both the Server Control and P.O.S. Control modules, modify the Bo.ini Configuration Key and Value, and only then start the Server again before redoing workstation data.