Technical Note: 20030528145
Cabling for CBM Serial Drawer with Status
You can use a CBM A08035-03 serial drawer with status.
Workstation |
To |
Cash Drawer |
|
(DB-9 Female) |
|
(CBM A08035-03-Black) |
|
3 |
To |
White wire |
(Drawer kick out) |
5 |
To |
Black wire |
(Ground) |
7 |
To |
Green or Blue wire |
(Drawer switch) |
9 |
To |
Red orOrange wire |
(Drawer switch) |
Connector body |
To |
Cable's shield |
|
4 and 6 |
Jumped together |
|
|
7 and 8 |
Jumped together |
|
|
Inside the drawer, make sure that the switch connections are:
Green wire on the connector on top of the switch,
White wire on the connector in the middle of the switch, and
Black wire on the connector next to the white wire.
Model tested: CBM A08035-03-Black