Technical Note: 20080219005

Enable CVM Re-Indexing

(Maitre'D 7.04.020.008 and later versions of 2005)

You can reflect modifier addition amongst existing modifiers in the same sequence on the CVM as on the Order screen. To position items properly when they are all sent to the kitchen in a batch, under the C:\Posera\MaitreD\Data directory, in the Pos??.ini file (you will need to do it for every Pos Ex.: Pos01.ini, Pos02.ini), add the following configuration key and value:

EnableCVMReIndexing= True

Note: If there is an AccuVIEW on the system, leave this value set to False, as this OCB only works with the On The Fly option enabled. Make sure to have a current version of the CVM software. The latest one is Version L.