Technical Note: 20011004043

Metrologic Orbit 7120 Serial Scanner Setup on JS170

(Maitre'D 2002, and later versions of Maitre'D)
Note: On the JS170 the on board MSR can only be a Keyboard Wedge (KBW) device. A KBW scanner WILL NOT RELIABLY OPERATE with a second KBW device (MSR). If you use the MSR on the JS170 then any scanner added MUST be serial to get continuously reliable scanning.

METROLOGIC 7120-41 (serial)

DO NOT USE Metrologic's MetrOPOS OPOSInstall.exe file.
Instead, use the codes provided below,
or obtain the OPOS ORBIT Config.rtf document from Metrologic at; http://www.metrologic.com/
Note: Right click in this window to print this document.

Setup OPOS

Step Bar code description

Bar Code

1 Enter / Exit program mode  
999999
2

Recall Defaults

 
999998
3

Enable RS232

 
415554
4

Enable LF

 
116612
5

Configuration Code #1

 
80752020
6

Configuration Code #2

 
807820
7

Configuration Code #3

 
80791330
8

Configuration Code #4

 
815980
10

Configuration Code #5

 
8166480
11

Configuration Code #6

 
8184120
12

Configuration Code #7

 
850610
13

Configuration Code #8

 
85101920
14

Configuration Code #9

 
85111860
15

Enter / Exit program mode

 
999999
16 Power the scanner off and on  

Program Scanner

Use the MetroSelect Configuration GuideĀ® that comes with the unit to scan the following bar codes:
Step Bar code description

Bar Code

Page

1 Enter / Exit configuration mode

 
999999

E1

2 Enable STX prefix

 
116615

E8

3

Enable C prefix

 
105511

E12

4

Enable CR suffix

 
116613

E14

5 Disable LF suffix

 
116602

E14

6 Disable ACK / NAK

 
115903

G9

7 Enter / Exit configuration mode

 
999999

E1

8 Power the scanner off and on

 

 

P.O.S. Control / Workstation / Option / Device

Type:

Select Serial.

Port:

Select the serial port of the scanner.
Note: The scanner cannot share this serial port with another device.

Driver: