Technical Note: 20051221025

Keep Reading in 24 Hours Operation

(Maitre'D 2005, from Service Pack 2 and later versions of 2005)

P.O.S. Control

To include the sales from before the End Of Day for employees whose shift starts before the EOD but print their server reading after it, in a restaurant running under 24 hours operation, add the following configuration key and value in the [Miscellaneous] section of the Bo.ini file under the C:\Posera\MaitreD\Data directory:

KeepReading24h=True

Note: You have to Reset the Server Reading at the end of the shift so that no sales are carried to the next shift.
Note: When modifying the Bo.ini, first stop the Server through Server Control, then exit both the Server Control and P.O.S. Control modules, modify the Bo.ini Configuration Key and Value, and only then start the Server again before redoing workstation data.