Technical Note: 20070611001b

Printout Target Reset of Broadcast

(Maitre'D 2005, from Service Pack 4 Hot Fix 8 and later versions of Maitre'D)

P.O.S. Control / Revenue Center / Items Setup / Configuration / Printing

If a Broadcast was prepared in an older service pack and transmitted to a restaurant with a later service pack, the 4 new printouts could revert to Receipt by default.

If so, to re-initialize File007.dat with printout 6 to 9 set to Null;

Note: You can fix all Broadcasts profiles using this tool if you install it in the MaitreD folder of the eGlobal server and run that command line.